Specifications CMS-E-ER 099182

If you are seeking Euchner CMS-E-ER 099182, connect FAMAGA, the world's influential vendor of streamlined equipment. Our company has progressed for more than ten years - these are years of experience, which are illustrated in the quality of outputs and special attention to each user. We understand everyone, who joined with us - hence, our regular buyers accept the most convenient purchase conditions and discounts on the manufacturing equipment market. Now, there are more than 4500 such clients, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the world . A well-developed logistics connection and a partnership network help us to send our goods anywhere in the globe immediately without discrediting product quality.

A specific source of good name for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the field of factory-made equipment.

All spare parts from FAMAGA are assured - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been supplied, and this quantity is rising every day. We are glad that customers choose FAMAGA again and again, and we strive to make more progressive and technologically advanced industrial equipment so as keep on top of it.

To inquire or book, get in touch with us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features CMS-E-ER 099182

  • Up to 30 read heads can be connected
  • 2 safety contacts
  • 1 auxiliary contact
  • 1 feedback loop can be connected
  • Start automatic/monitored/not monitored
Functional The evaluation unit CMS-E-ER is suitable for the direct connection of up to 30 read heads. Category/PL according to EN ISO 13849-1
  • Category 3/PL d with more than one read head connected
  • Category 4/PL e with only one read head connected
Notice:At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 0.6 ms. Dimension drawing Wiring diagram CMS: Magnetically coded safety switches Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,22 kg
Ambient temperature 0 ... 55 °C
Degree of protection Terminals IP20 / housing IP40
Mechanical life 10 x 106
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Safety contacts 13/14 and 23/24
Number of safety contacts 2
Auxiliary contacts 31/32
Number of auxiliary contacts 1
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10% V
Fusing
Protection internal (operating voltage UB) 0,75 A Automatically resetting fuse PTC
Rated insulation voltage Ui
AC 250 V
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm?
LED indicator 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2)
Safety contacts 13/14 and 23/24
Type of output Relay contacts, floating
Current consumption
at DC 24V 10 ... 110 mA
Switching voltage max.240 V
Switching current
at DC 24V 10 ... 3000 mA
Fusing
External contact fuse (safety circuit) acc. to EN IEC 60269-1 4A gG
Utilization category according to EN 60947-4-1
Utilization category according to EN 60947-5-1
AC-15 0.9A , 240V and 0.9A , 24V
DC-13 1.5A , 24V
Switching load
According to UL class 2 Input: 24V AC/DC , output: 30V AC, 24V DC
Breaking capacity (VA) max.720 VA
Risk time according to EN 60947-5-3 20 ms
Auxiliary contacts 31/32
Type of output Relay contacts, floating
Switching current
at DC 24V max.1500 mA
Other
In compliance with EN ISO 13849-1: 2015, EN ISO 13849-2:2012, EN 50178: 1997, EN 60204-1: 2006/A1: 2009, EN ISO 13850: 2015, EN 14119:2013, EN 6100-6-2: 2005, EN 6100-6-3: 2007/A1: 2011, EN 60947-5-3: 2013
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category
With one read head 4
With more than one read head 3
Performance Level
With more than one read head PL d
With one read head PL e
PFHD
With more than one read head 1.0 x 10-7
With one read head 2.5 x 10-8
Number of switching cycles
? 1A at 24V DC 70000 1/Jahr
? 0.1A at 24V DC 166000 1/Jahr
Mission time 20 y
In combination with Read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and Actuator CMS-MH-AAOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao
With center offset m=0 min.10 mm
In combination with Read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and Actuator CMS-MH-BBOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.13 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EFOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.17 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC and Actuator CMS-M-ACOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.31 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and Actuator CMS-M-BDOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.12 mm
Assured operating distance Sao
With center offset m=0 min.3 mm
In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CAOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.14 mm
Assured operating distance Sao
With center offset m=0 min.6 mm