We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner CMS-E-ER 099182, connect FAMAGA, the world's influential vendor of streamlined equipment. Our company has progressed for more than ten years - these are years of experience, which are illustrated in the quality of outputs and special attention to each user. We understand everyone, who joined with us - hence, our regular buyers accept the most convenient purchase conditions and discounts on the manufacturing equipment market. Now, there are more than 4500 such clients, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the world Germany, United Kingdom, Lithuania, Kazakhstan, Guatemala, Gambia, Bolivia, Cameroon, Swaziland, Equatorial Guinea, New Zealand, Central African Republic, Bulgaria, Vietnam, Burkina Faso, North Korea, Angola, Nicaragua, Bosnia and Herzegovina, Sudan, Uruguay, Turkey, Mauritius, Belize, United States, Moldova, South Sudan, Burundi, Mongolia, Egypt, Iraq, Mauritania, Macedonia, Antigua and Barbuda, Uganda, Slovakia, Rwanda, China, Niger, Norway, Kiribati, Kyrgyzstan, Denmark, Yemen. A well-developed logistics connection and a partnership network help us to send our goods anywhere in the globe immediately without discrediting product quality.
A specific source of good name for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the field of factory-made equipment.
All spare parts from FAMAGA are assured - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been supplied, and this quantity is rising every day. We are glad that customers choose FAMAGA again and again, and we strive to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To inquire or book, get in touch with us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
Housing material | Polyamide PA6.6 |
Weight | |
Net | 0,22 kg |
Ambient temperature | 0 ... 55 °C |
Degree of protection | Terminals IP20 / housing IP40 |
Mechanical life | 10 x 106 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Safety contacts 13/14 and 23/24 | |
Number of safety contacts | 2 |
Auxiliary contacts 31/32 | |
Number of auxiliary contacts | 1 |
Operating voltage | |
AC/DC | 24 V -10% ... +10% V |
Fusing | |
Protection internal (operating voltage UB) | 0,75 A Automatically resetting fuse PTC |
Rated insulation voltage Ui | |
AC | 250 V |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm? |
LED indicator | 1 indicator LED Power (UB) and 2 status indicators for the read heads (K1/K2) |
Safety contacts 13/14 and 23/24 | |
Type of output | Relay contacts, floating |
Current consumption | |
at DC 24V | 10 ... 110 mA |
Switching voltage | max.240 V |
Switching current | |
at DC 24V | 10 ... 3000 mA |
Fusing | |
External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 4A gG |
Utilization category according to EN 60947-4-1 | |
Utilization category according to EN 60947-5-1 | |
AC-15 | 0.9A , 240V and 0.9A , 24V |
DC-13 | 1.5A , 24V |
Switching load | |
According to UL class 2 | Input: 24V AC/DC , output: 30V AC, 24V DC |
Breaking capacity (VA) | max.720 VA |
Risk time according to EN 60947-5-3 | 20 ms |
Auxiliary contacts 31/32 | |
Type of output | Relay contacts, floating |
Switching current | |
at DC 24V | max.1500 mA |
In compliance with | EN ISO 13849-1: 2015, EN ISO 13849-2:2012, EN 50178: 1997, EN 60204-1: 2006/A1: 2009, EN ISO 13850: 2015, EN 14119:2013, EN 6100-6-2: 2005, EN 6100-6-3: 2007/A1: 2011, EN 60947-5-3: 2013 |
Monitoring of the safety guard position | |
Category | |
With one read head | 4 |
With more than one read head | 3 |
Performance Level | |
With more than one read head | PL d |
With one read head | PL e |
PFHD | |
With more than one read head | 1.0 x 10-7 |
With one read head | 2.5 x 10-8 |
Number of switching cycles | |
? 1A at 24V DC | 70000 1/Jahr |
? 0.1A at 24V DC | 166000 1/Jahr |
Mission time | 20 y |
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.20 mm |
Assured operating distance Sao | |
With center offset m=0 | min.10 mm |
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.13 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.17 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.31 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.12 mm |
Assured operating distance Sao | |
With center offset m=0 | min.3 mm |
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.14 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |