We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CES-AR-C01-CH-SA
Part number
098942
Description
Berührungsloser Sicherheitsschalter CES-AR-C01-CH-SA
Stock availability:
On request
If you are inspecting Euchner CES-AR-C01-CH-SA 098942, make contact with FAMAGA, the world's foremost distributor of machine made equipment. Our company has progressed for more than ten years - these are ages of experience, which are expressed in the quality of outcomes and special attention to each user. We praise everyone, who engaged with us - so, our regular buyers accept the most desirable purchase conditions and discounts on the factory-made equipment market. Today, there are more than 4 thousand such customers, and we constantly make new agreements. More than 600 affairs are settled per day, because FAMAGA works all over the globe Germany, United Kingdom, Benin, Brunei, Hungary, Fiji, India, Qatar, New Zealand, Tajikistan, Syria, Mauritius, Kuwait, Macedonia, Czech Republic, Panama, Cameroon, Belize, Romania, Zimbabwe, East Timor, Morocco, Sierra Leone, Georgia, Slovakia, Mauritania, Jordan, Jamaica, Samoa, Israel, Nicaragua, Rwanda, Estonia, Croatia, Costa Rica, South Korea, Comoros, Iceland, Burkina Faso, Djibouti, Luxembourg, Mexico, Switzerland, Australia. A well-built logistics series and a partnership network guide us to dispatch our items anywhere in the world immediately without discrediting product quality.
A particular source of pride for FAMAGA is its team members, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the range of industrial equipment.
All outputs from FAMAGA are assured - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been shipped, and this amount is rising every day. We are happy that consumers choose FAMAGA again and again, and we are happy to make more developed and technologically developed industrial equipment so as to stay on the top.
To consult or place an order, phone us or send a message to the online chat on our site. You can also dispatch a list of the required equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
OUT | Monitoring output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | IB | Enable input for channel 2 | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | OUT | Monitoring output | GY | |
6 | IA | Enable input for channel 1 | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,12 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting distance | min.40 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | M12 plug connector, 8-pin |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
No load on outputs | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | max.200 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.1 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 400 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5 ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 400mA |
Rated conditional short-circuit current | max.100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.1 x 10-9 |
Mission time | 20 |
Switch-on distance | 18 mm |
Assured switch-off distance Sar | max.45 mm |
Assured operating distance Sao | min.15 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 22 mm |
Assured switch-off distance Sar | max.58 mm |
Assured operating distance Sao | min.18 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 27 mm |
Assured switch-off distance Sar | max.75 mm |
Assured operating distance Sao | min.20 mm |
Switching hysteresis | 3 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | max.45 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |