We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Euchner ESM-BA701P 097225, reach FAMAGA, the world's leading supplier of industrialized equipment. Our company has existed for more than ten years - these are ages of experience, which are expressed in the quality of products and particular attention to each client. We admire everyone, who cooperated with us - therefore, our regular purchasers receive the most acceptable purchase terms and discounts on the industrial equipment market. At present, there are more than 4500 such buyers, and we constantly arrange new agreements. More than 650 purchases are terminated per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Cambodia, Central African Republic, Zimbabwe, Laos, Latvia, Chile, Liberia, Azerbaijan, Burundi, Gambia, Mexico, Lebanon, Israel, Ireland, Ecuador, Samoa, Ukraine, Panama, Andorra, Malaysia, Japan, Kenya, Argentina, Costa Rica, Algeria, Botswana, Moldova, Australia, Tajikistan, Mongolia, Turkmenistan, Montenegro, Niger, Armenia, Angola, Bosnia and Herzegovina, Antigua and Barbuda, Brunei, Sierra Leone, Austria, Bulgaria, Croatia, Czech Republic, Kiribati. A well-shaped logistics system and a partnership network assist us to deliver our products anywhere in the world on-time without damaging product quality.
A particular source of honor for FAMAGA is its personnel, each of whom contributes to our work. We call into our team only experts, who already have experience in the direction of industrial equipment.
All products from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been shipped, and this number is amounting every day. We are glad that buyers choose FAMAGA again and again, and we are glad to make more advanced and technologically innovative industrial equipment so as keep on top of it.
To ask a question or place an order, call us by phone or write to the online chat on our site. You can also forward a list of the required equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
Housing material | Polyamide PA6.6 |
Weight | |
Net | 0,35 kg |
Ambient temperature | -15 ... 40 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Number of monitoring outputs | 2 semiconductor outputs |
Connection | Plug-in connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Monitoring outputs 01 / 02 | |
Number of monitoring contacts | 2 |
Auxiliary contacts 43/44, 53/54, 63/64, 73/74, 101/102, 101/112 | |
Number of auxiliary contacts | 4 |
Safety contacts 13/14, 23/24, 33/34, 81/82, 91/92 | |
Number of safety contacts | 7 |
Operating voltage | |
AC/DC | 24 V -10% ... +10% |
Power consumption (apparent power) | |
At 24V AC | 8,5 VA |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Reverse polarity protection | |
On version UB=24V DC | |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connecting cable | |
at 24V DC | 4,5 |
Connection cross-section | 0,14 ... 2,5 mm? Connection terminal (size) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V 18,6 ... 26 V Start button |
Control current | |
S11...S14 | 250 mA |
LED indicator | 1 status displays operating voltage (Pwr), 2 status displays (green) for relays K1 and K2 |
Monitoring outputs 01 / 02 | |
Type of output | |
Semiconductor output PNP | Short circuit-proof |
Output voltage | 24 V DC |
Output current | max.30 mA |
Auxiliary contacts 43/44, 53/54, 63/64, 73/74, 101/102, 101/112 | |
Type of output | |
NO contact / NC contact | Relay contacts, floating |
Utilization category according to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 8A, 250V |
DC-12 | 8A ohmic load, 50V |
Breaking capacity according to UL | |
Auxiliary contact | 2A 250V AC / 1.5A 24V DC |
Safety contacts 13/14, 23/24, 33/34, 81/82, 91/92 | |
Type of output | |
NO contact / NC contact | Relay contacts, floating and positively driven (redundant) |
Switching voltage | |
AC | max.250 V |
DC | max.50 V |
Switching current | min.5 mA at 24V |
Cumulative current | max.35 A For all contacts |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10AgG (T6A / F8A) |
Utilization category according to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 8A ohmic load, 250V |
DC-12 | 8A ohmic load, 50V |
Breaking capacity according to UL | |
Safety contacts | 8A 250V AC / 2A 24V DC per contact |
In compliance with | EN 60439-1:1999+A1:2004 , EN 60947-1:2007 , EN 60947-5-1:2004 , EN 60947-7-1:2002 , EN 61000-6-2:2005 , EN 61000-6-3:2007 , EN ISO 13849-1:2008 , EN 62061:2005 , EN 60204-1:2007 |
Performance Level | PL e |
Category | 4 |
PFHD | 2.47 x 10-8 |
Number of switching cycles | |
? 0.1 A at 24 V DC | max.500000 1/Jahr |
? 2 A at 24 V DC | max.100000 1/Jahr |
? 1 A at 24 V DC | max.350000 1/Jahr |
Mission time | 20 y |