We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are inspecting Euchner TZ1RE024RC18VAB-C1828 090353, reach FAMAGA, the world's principle distributor of machine made equipment. Our company has progressed for more than ten years - these are ages of experience, which are portrayed in the quality of items and special attention to each orderer. We admire everyone, who joined with us - hence, our regular purchasers accept the most attractive purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4 thousand such buyers, and we constantly arrange new agreements. More than 750 agreements are achieved per day, because FAMAGA supplies all over the planet Germany, United Kingdom, Brazil, Mauritania, Rwanda, El Salvador, Switzerland, Equatorial Guinea, Colombia, Latvia, Bulgaria, Canada, Bahamas, Moldova, Benin, Uganda, Botswana, Laos, Monaco, Comoros, Andorra, Tonga, Jamaica, Uzbekistan, Kuwait, Cape Verde, Madagascar, Morocco, South Korea, South Sudan, Kyrgyzstan, Mexico, Malta, Poland, Nicaragua, Nepal, Mozambique, Mongolia, Zimbabwe, Iceland, Pakistan, Finland, North Korea, Vietnam, Hungary, Qatar, Yemen. A well-elaborated logistics connection and a partnership network cheer us to ship our goods anywhere in the planet immediately without damaging product quality.
A particular source of dignity for FAMAGA is its staff members, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the direction of manufacturing equipment.
All outputs from FAMAGA are verified - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been provided, and this amount is rising every day. We are happy that clients choose FAMAGA again and again, and we are happy to make more progressive and technologically innovative industrial equipment so as keep on top of it.
To get some advice or make a request, phone us or write a message to the online chat on our site. You can also forward a list of the necessary equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
TZ1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. |
SK | For monitoring the door/actuator position |
UK | For monitoring the guard locking (built-in solenoid) |
2131H | Slow-action switching contact 3 NC + 1 NO |
3131H | Slow-action switching contact 2 NC + 2 NO |
Housing material | Anodized die-cast alloy |
Weight | |
Net | 1,2 kg |
Ambient temperature | -25 ... 80 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 3 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 2 |
Connection | |
1 x | Plug connector RC18 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Retention force | 10 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.52 mm |
Cover lid | Black |
Thermal rated current Ith | 4 A 70°C => 2A'> |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 110V 70°C => 2A'> |
DC-13 | 4A 24V 70°C => 2A'> |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG 70°C => 2A gG'> |
Rated insulation voltage Ui | 110 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 10 W |
Solenoid duty cycle | 100 % |
LED indicator | Operating voltage corresponds to the solenoid voltage |
C number | |
C1828 | With escape release, special wiring |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 3 x 106 |
Overtravel | 4 mm |
Overtravel | 16 mm |