We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Euchner TZ1LE024RC18VAB-C1828 090352, contact FAMAGA, the world's primary producer of manufacturing equipment. Our company has worked for more than ten years - these are cycles of experience, which are symbolized in the quality of products and particular attention to each user. We value everyone, who collaborated with us - therefore, our regular buyers obtain the most helpful purchase forms and discounts on the manufacturing equipment market. At present, there are more than 4500 such purchasers, and we constantly sign new agreements. More than 600 purchases are terminated per day, because FAMAGA operates all over the earth Germany, United Kingdom, Guatemala, Chile, Poland, Burundi, Kenya, Costa Rica, Lebanon, Ghana, Brunei, Guinea, Myanmar, Ireland, Argentina, Syria, Namibia, Albania, Gambia, Paraguay, Cyprus, Qatar, Cameroon, Guyana, Iran, Armenia, Montenegro, New Zealand, Rwanda, Ecuador, Mozambique, Austria, Croatia, Kyrgyzstan, Liechtenstein, Australia, Czech Republic, Peru, Sierra Leone, Serbia, Mali, Lithuania, Malaysia, Norway, Burkina Faso, Andorra, Turkey. A advanced logistics chains and a partnership network let us to send our elements anywhere in the earth promptly without discrediting product quality.
A special source of pride for FAMAGA is its personnel, each of whom contributes to common cause. We propose into our team only professionals, who already have experience in the field of machine made streamlined equipment.
All goods from FAMAGA are guaranteed - we are responsible for the outcome of our work. At this moment, more than 10 million units of products have been delivered, and this quantity is amounting every day. We are glad that users choose FAMAGA again and again, and we strive to make more advanced and technologically advanced industrial equipment so as to stay on the top.
To consult or place an order, get in touch with us or write to the online chat on our site. You can also send a list of the needful equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
TZ1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. |
SK | For monitoring the door/actuator position |
UK | For monitoring the guard locking (built-in solenoid) |
2131H | Slow-action switching contact 3 NC + 1 NO |
3131H | Slow-action switching contact 2 NC + 2 NO |
Housing material | Anodized die-cast alloy |
Weight | |
Net | 1,2 kg |
Ambient temperature | -25 ... 80 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 3 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 2 |
Connection | |
1 x | Plug connector RC18 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Retention force | 10 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.52 mm |
Cover lid | Black |
Thermal rated current Ith | 4 A 70°C => 2A'> |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 110V 70°C => 2A'> |
DC-13 | 4A 24V 70°C => 2A'> |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG 70°C => 2A gG'> |
Rated insulation voltage Ui | 110 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 10 W |
Solenoid duty cycle | 100 % |
LED indicator | Operating voltage corresponds to the solenoid voltage |
C number | |
C1828 | With escape release, special wiring |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 3 x 106 |
Overtravel | 16 mm |
Overtravel | 4 mm |