Specifications ESM-BT421-50S 090094

If you are looking for Euchner ESM-BT421-50S 090094, make contact with FAMAGA, the world's central supplier of factory-made equipment. Our company has existed for more than ten years - these are years of experience, which are described in the quality of outputs and individual attention to each consumer. We admire everyone, who cooperated with us - thus, our regular clients receive the most desirable purchase conditions and discounts on the manufacturing equipment market. Today, there are more than 4500 such clients, and we constantly compose new agreements. More than 750 purchases are terminated per day, because FAMAGA delivers all over the earth . A advanced logistics bond and a partnership network assist us to conduct our items anywhere in the earth quickly without undermining product quality.

A special source of good name for FAMAGA is its workers, each of whom contributes to common cause. We propose into our team only specialists, who already have experience in the direction of machine made streamlined equipment.

All goods from FAMAGA are ensured - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is increasing every day. We are glad that users choose FAMAGA again and again, and we are pleased to make more progressive and technologically advanced industrial equipment so as stay in control.

To inquire or make a request, contact us or write to the online chat on our site. You can also dispatch a list of the needful equipment to the email of organization - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features ESM-BT421-50S 090094

  • Usage up to category 4 according to EN ISO 13849-1
  • LED status indicators
  • 1-channel or 2-channel control
  • 4 redundant safety contacts of which 1 contact time-delayed
  • Time delay 5 s
  • Short circuit and earth fault/ground fault monitoring
Relay outputsThe outputs are electrically decoupled and of redundant design. Connection optionsBy using suitable wiring the following functions can be selected:
  • Relay start with automatic start, a start button or a monitored start button
  • Monitoring of downstream relays or contactors
  • Simultaneity monitoring to monitor safety components over time
  • Relay start using a monitored start button
  • Short circuit monitoring to detect short circuits between the connection cables and to shut down the outputs or prevent relay starting if necessary
  • Earth fault/ground fault monitoring to detect short circuits between the connection cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Time-delayed shutdownTime delay 5 s Dimension drawing ESM-BT421 Dimension drawingESM-BT421 Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,25 kg
Ambient temperature -15 ... 40 °C
Degree of protection IP20
Mechanical life
operating cycles 10 x 106
Contact material AgSnO2
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Length of control cable
With conductor cross-section 0.75mm2 1000 m
Safety contacts 13/14, 23/24, 33/34, 47/48
Number of safety contacts 4
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10%
Power consumption (apparent power)
At 24V AC 5,3 VA
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp
Leakage path/air gaps 4 kV
Reverse polarity protection
On version UB =24V DC
Rated supply frequency 50 ... 60 Hz
Power consumption
at 24V DC 4,7 W
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm? Connection terminal (size)
Test voltage
Control system/contacts 2,5 kV
Control voltage
On S11 24 V 18,6 ... 26 V Start button
Control current 190 mA
Drop-out delay
at 24V DC max.30 ms Emergency stop
At 24V AC max.20 ms Emergency stop
LED indicator 4 status displays (green) for relays K1, K2, K3, K4
Safety contacts 13/14, 23/24, 33/34, 47/48
Type of output
NO Relay contacts positively driven (redundant)
Switching voltage
AC max.250 V
DC max.50 V
Switching current min.5 mA at 24V
Cumulative current max.15 A For all contacts
Fusing
External contact fuses (safety circuit) according to IEC 60269-1 10A gG (T6A / F8A)
Utilization category according to EN 60947-5-1
AC-15 3A, 250V
DC-13 3A, 24V
AC-12 8A ohmic load, 250V
DC-12 8A ohmic load, 50V
Switching characteristics 3 safety contacts non-delayed, 1 safety contact time-delayed
Delay time
Fixed 5 s
Other
In compliance with EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007
Reliability values according to EN ISO 13849-1
Performance Level PL e
Category
Safety contacts non-time-delay 4
Safety contacts time-delay 3
PFHD
Safety contacts time-delay 8.84 x 10-8
Safety contacts non-time-delay 4.22 x 10-8
Number of switching cycles
? 2 A at 24 V DC max.100000 1/Jahr
? 0.1 A at 24 V DC max.500000 1/Jahr
? 1 A at 24 V DC max.350000 1/Jahr
Mission time 20 y