We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are inspecting Euchner ESM-BT411-20S 090077, communicate with FAMAGA, the world's main retailer of machine made equipment. Our company has functioned for more than ten years - these are ages of experience, which are represented in the quality of products and private attention to each purchaser. We cherish everyone, who liased with us - hence, our regular customers bring in the most helpful purchase forms and discounts on the factory-made equipment market. Nowadays, there are more than 4500 such consumers, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Paraguay, Latvia, Senegal, Panama, Albania, Slovenia, The Bahamas, Sweden, Bangladesh, Nicaragua, Netherlands, Libya, Mozambique, Honduras, Poland, Slovakia, Georgia, Nepal, Armenia, India, Bolivia, Cameroon, Haiti, Benin, Dominica, Tajikistan, Brunei, Qatar, Turkey, Morocco, Macedonia, Yemen, Zimbabwe, Swaziland, Niger, Croatia, Brazil, South Korea, Belarus, Kiribati, Peru, Montenegro, Cape Verde, Mauritius. A well-built logistics connection and a partnership network cheer us to dispatch our goods anywhere in the earth with no delay without compromising product quality.
A particular source of dignity for FAMAGA is its employees, each of whom contributes to common cause. We request into our team only experts, who already have experience in the direction of manufacturing equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this amount is growing every day. We are glad that buyers choose FAMAGA again and again, and we strive to make more progressive and technologically innovative industrial equipment so as keep on top of it.
To consult or order, get in touch with us or write a message to the online chat on our site. You can also forward a list of the needful equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
Housing material | Polyamide PA6.6 |
Weight | |
Net | 0,25 kg |
Ambient temperature | -15 ... 40 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24, 37/38, 47/48 | |
Number of safety contacts | 4 |
Operating voltage | |
AC/DC | 24 V -10% ... +10% |
Power consumption (apparent power) | |
At 24V AC | 5,3 VA |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Reverse polarity protection | |
On version UB =24V DC | |
Rated supply frequency | 50 ... 60 Hz |
Power consumption | |
at 24V DC | 4,7 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm? Connection terminal (size) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V 18,6 ... 26 V Start button |
Control current | 190 mA |
Drop-out delay | max.20 ms Emergency stop |
LED indicator | 4 status displays (green) for relays K1, K2, K3, K4 |
Safety contacts 13/14, 23/24, 37/38, 47/48 | |
Type of output | |
NO | Relay contacts positively driven (redundant) |
Switching voltage | |
AC | max.250 V |
DC | max.50 V |
Switching current | min.5 mA at 24V |
Cumulative current | max.15 A For all contacts |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG (T6A / F8A) |
Utilization category according to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 8A ohmic load, 250V |
DC-12 | 8A ohmic load, 50V |
Switching characteristics | 2 safety contacts non-delayed, 2 safety contacts time-delayed |
Delay time | |
Fixed | 2 s |
In compliance with | EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007 |
Performance Level | PL e |
Category | |
Safety contacts non-time-delay | 4 |
Safety contacts time-delay | 3 |
PFHD | |
Safety contacts time-delay | 8.84 x 10-8 |
Safety contacts non-time-delay | 4.22 x 10-8 |
Number of switching cycles | |
? 0.1 A at 24 V DC | max.500000 1/Jahr |
? 2 A at 24 V DC | max.100000 1/Jahr |
? 1 A at 24 V DC | max.350000 1/Jahr |
Mission time | 20 y |