TZ1LE110M-C1684 Euchner 089924
 TZ1LE110M-C1684 Euchner 089924

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

TZ1LE110M-C1684 089924 Euchner

Manufacturer

Euchner

Country

Germany

Name

TZ1LE110M-C1684

Part number

089924

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications TZ1LE110M-C1684 089924

If you are questing Euchner TZ1LE110M-C1684 089924, make contact with FAMAGA, the world's major retailer of industrialized equipment. Our company has progressed for more than ten years - these are years of experience, which are depicted in the quality of outputs and particular attention to each user. We praise everyone, who liased with us - hence, our regular purchasers accept the most desirable purchase terms and discounts on the manufacturing equipment market. Nowadays, there are more than 3500 such purchasers, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA delivers all over the globe . A well-elaborated logistics link and a partnership network cheer us to dispatch our goods anywhere in the world immediately without damaging product quality.

A specific source of repute for FAMAGA is its staff members, each of whom contributes to common cause. We call into our team only specialists, who already have experience in the range of industrial equipment.

All merchandises from FAMAGA are affirmed - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been shipped, and this quantity is amounting every day. We are pleased that customers choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as stay in control.

To request or place an order, get in touch with us or write a message to the online chat on our official website. You can also dispatch a list of the required equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features TZ1LE110M-C1684 089924

  • Auxiliary release on the front
  • Escape release on the rear with pushbutton
  • Two LED indicators, red and green
  • Actuating head fitted left
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
  • 110 V AC -15%, +10%
Guard locking type
TZ1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
Switching element
SKFor monitoring the door/actuator position
UKFor monitoring the guard locking (built-in solenoid)
528HSlow-action switching contact 1 NC + 1 NO
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors). Escape releaseThis is used for manual release of guard locking from within the danger area without tools.
Housing material Anodized die-cast alloy
Weight
Net 1,2 kg
Ambient temperature -25 ... 80 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 1
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 1
Number of guard lock monitoring NO contacts 1
Connection
1 x M20 x 1.5
Approach speed max.20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 2000 N
Locking force FZh 1500 N
Retention force 10 N
Extraction force 30 N
Actuating force 35 N
Insertion depth min.52 mm
Cover lid Black
Electrical connection ratings
Thermal rated current Ith 4 A 70°C => 2A'>
Utilization category according to EN 60947-5-1
AC-15 4A 230V 70°C => 2A'>
DC-13 4A 24V 70°C => 2A'>
Solenoid operating voltage
AC 110 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG 70°C => 2A gG'>
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 10 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
LED indicator Operating voltage corresponds to the solenoid voltage
Other
C number
C1684 with escape release
Reliability values according to EN ISO 13849-1
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-Z-GMechanical values and environment
Overtravel 4 mm
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
Overtravel 16 mm