If you are questing Euchner ESM-BL203 085609, catch up with FAMAGA, the world's the best supplier of machine made equipment. Our company has progressed for more than ten years - these are cycles of experience, which are symbolized in the quality of merchandises and particular attention to each buyer. We value everyone, who joined with us - so, our regular customers receive the most convenient purchase forms and discounts on the machine made streamlined equipment market. Now, there are more than 4000 such purchasers, and we constantly form new agreements. More than 600 affairs are settled per day, because FAMAGA works all over the globe Germany, United Kingdom, Dominican Republic, Georgia, United Arab Emirates, Tajikistan, Tanzania, Botswana, Cape Verde, Slovenia, Russia, East Timor, Bahamas, Ghana, Zimbabwe, Mauritius, Guatemala, Benin, Finland, Samoa, Albania, South Sudan, Austria, Fiji, Monaco, Greece, Burundi, Croatia, Mexico, Mauritania, Senegal, Panama, Central African Republic, Seychelles, United States, Estonia, Cameroon, Indonesia, Tonga, Togo, Bosnia and Herzegovina, China, Jordan, Chile, Cyprus, Nepal. A advanced logistics connection and a partnership network cheer us to deliver our products anywhere in the world immediately without compromising product quality.
A specific source of dignity for FAMAGA is its personnel, each of whom contributes to our work. We propose into our team only specialists, who already have experience in the sphere of factory-made equipment.
All products from FAMAGA are verified - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been delivered, and this number is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we are happy to make more developed and technologically modern industrial equipment so as to stay on the top.
To get some advice or order, contact us or send a message to the online chat on our official website. You can also direct a list of the desirable equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Housing material | Polyamide PA6.6 |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 115/230V AC | -15 ... 40 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgNi-10 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 |
Operating voltage | |
AC | 230 V -10% ... +10% |
Power consumption (apparent power) | |
At 230 V AC | 3,5 VA |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Rated supply frequency | 50 ... 60 Hz |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm? Connection terminal (size) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V 18,6 ... 26 V Start button |
Control current | |
S11...S14 | 40 mA |
LED indicator | 2 status displays (green) for relays K1 and K2 |
Safety contacts 13/14, 23/24 | |
Type of output | |
NO | Relay contacts floating and positively driven (redundant) |
Switching voltage | |
AC | max.250 V |
DC | max.24 V |
Switching current | min.20 mA at 24V |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG (T4A / F6A) |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A, 250V |
DC-13 | 2A, 24V |
AC-12 | 6A ohmic load, 250V |
DC-12 | 1.25A ohmic load, 24V |
Breaking capacity according to UL | 6A 250V AC / 2A 24V DC |
In compliance with | EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007 |
Performance Level | PL d |
Category | 3 |
PFHD | 1.03 x 10-7 |
Number of switching cycles | |
? 0.1 A at 24 V DC | max.400000 1/Jahr |
? 1 A at 24 V DC | max.73000 1/Jahr |
? 2 A at 24 V DC | max.17000 1/Jahr |
Mission time | 20 y |