We are not the manufacturer, authorised distributor or authorised representative of the Aventics (brand of Emerson) brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Aventics (brand of Emerson)
Country
Germany
Part number
0820060361
Description
Actuating control | single solenoid |
Return type | With spring/air spring return |
Switching principle | 5/2 |
Version | Spool valve, positive overlapping |
Housing | Polyamide fiber-glass reinforced |
Sealing material | Acrylonitrile butadiene rubber,Polyurethane |
Connector standard | DIN EN 60947-5-2 |
Protection class | IP65 |
Number of wires | 4-pin |
Port size | M8 |
Type | Plug |
Nominal flow Qn | 800 l/min |
Compressed air connection input | G 1/8 |
Compressed air connection output | G 1/8 |
DC operating voltage | 24 V |
Activation | Electrically |
Stock availability:
On request
If you are looking for Aventics (brand of Emerson) 0820060361, reach FAMAGA, the world's prime provider of streamlined equipment. Our company has existed for more than ten years - these are ages of experience, which are portrayed in the quality of products and particular attention to each user. We understand everyone, who engaged with us - hence, our regular buyers get the most favorable purchase terms and discounts on the machine made streamlined equipment market. At present, there are more than 4000 such purchasers, and we constantly sign new agreements. More than 650 affairs are settled per day, because FAMAGA supplies all over the world Germany, United Kingdom, Comoros, Bosnia and Herzegovina, Côte d\'Ivoire, Austria, El Salvador, Botswana, Tonga, New Zealand, Bhutan, Canada, Denmark, Slovenia, Sierra Leone, Niger, Costa Rica, Ireland, Uruguay, Kenya, Norway, Latvia, Ghana, Bolivia, Namibia, Panama, Chile, Sweden, India, Uganda, Bangladesh, Mongolia, Luxembourg, Iran, Afghanistan, Azerbaijan, Yemen, United States, Greece, Lithuania, Samoa, Bulgaria, Albania, Armenia, Brazil, Equatorial Guinea, Czech Republic. A well-shaped logistics series and a partnership network guide us to ship our elements anywhere in the world immediately without discrediting product quality.
A specific source of repute for FAMAGA is its staff members, each of whom contributes to our work. We call into our team only experts, who already have experience in the field of factory-made equipment.
All outcomes from FAMAGA are assured - we are responsible for the result of our work. At the moment, more than 10 million units of products have been shipped, and this bulk is rising every day. We are proud that clients choose FAMAGA again and again, and we are eager to make more advanced and technologically modern industrial equipment so as keep on top of it.
To ask a question or order, call us by phone or send a message to the online chat on our official website. You can also forward a list of the required equipment to the email of firm - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
Version | Spool valve, positive overlapping |
Activation | Electrically |
Sealing principle | Soft sealing |
Working pressure min./max. | See table |
Control pressure min./max. | See table |
Ambient temperature min./max. | -10 ... 50 °C |
Medium temperature min./max. | -10 ... 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 ... 5 mg/m³ |
Nominal flow Qn | 800 l/min |
Connector standard | DIN EN 60947-5-2 |
Protection class acc. to DIN EN 61140 Electrically | Class III |
Protection class with connection | IP65 |
LED status display | Yellow |
Duty cycle | 100 % |
Mounting on manifold strip | P-strip |
Mounting screw tightening torque | 2 Nm |
Weight | See table |
Comment | An example configuration is illustrated. The delivered product may thus deviate from the illustration. |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber Polyurethane |
Front plate | Polyamide fiber-glass reinforced |
Threaded bushing | Brass Die cast zinc, nickel-plated chrome-plated |