Manufacturer
Aventics (brand of Emerson)
Country
Germany
Part number
5794475270
Description
Version | Poppet valve |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber,Polyurethane |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Nominal flow Qn | 520 l/min |
Compressed air connection input | Ø 6x1 |
Compressed air connection output | Ø 6x1 |
Operational voltage AC at 50 Hz | 110 V |
Operational voltage AC at 60 Hz | 110 V |
Activation | Electrically |
Stock availability:
On request
If you are pursuing Aventics (brand of Emerson) 5794475270, call FAMAGA, the world's prime supplier of factory-made equipment. Our company has operated for more than ten years - these are years of experience, which are portrayed in the quality of items and special attention to each consumer. We understand everyone, who cooperated with us - so, our regular customers pick up the most acceptable purchase conditions and discounts on the manufacturing equipment market. At present, there are more than 4000 such buyers, and we constantly arrange new agreements. More than 700 transactions are made per day, because FAMAGA supplies all over the planet Germany, United Kingdom, El Salvador, Myanmar, Burma, East Timor, Montenegro, China, Guyana, Brunei, Angola, Serbia, Iceland, Mongolia, Liechtenstein, Estonia, Kenya, Bangladesh, Gambia, Uruguay, Tonga, Malaysia, Iran, Tajikistan, Austria, Netherlands, Andorra, Tunisia, Burkina Faso, Slovakia, Nicaragua, Bosnia and Herzegovina, India, Afghanistan, Moldova, Bulgaria, Benin, Equatorial Guinea, Yemen, Iraq, Guatemala, Zambia, Israel, Cameroon, New Zealand, Central African Republic, Eswatini. A well-elaborated logistics bond and a partnership network guide us to send our elements anywhere in the globe as soon as possible without compromising product quality.
A special source of honor for FAMAGA is its personnel, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the range of factory-made equipment.
All outputs from FAMAGA are affirmed - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been shipped, and this quantity is amounting every day. We are pleased that customers choose FAMAGA again and again, and we strive to make more developed and technologically advanced industrial equipment so as to stay on the top.
To request or make a request, phone us or write to the online chat on our official website. You can also forward a list of the necessary equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
Version | Poppet valve |
Activation | Electrically |
Pilot | External |
Sealing principle | Soft sealing |
Working pressure min./max. | 0,5 ... 8 bar |
Control pressure min./max. | 2 ... 8 bar |
Ambient temperature min./max. | -15 ... 50 °C |
Medium temperature min./max. | -15 ... 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 ... 1 mg/m³ |
Nominal flow Qn | See table |
Protection class with connection | IP65 |
Reverse polarity protection | Protected against polarity reversal |
Duty cycle | 100 % |
Typ. switch-on time | 18 ms |
Typ. switch-off time | 16 ms |
Weight | 0,093 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
At an ambient temperature of 40 °C the max. working pressure is 10 bar . Versions with voltage of less than 50 V DC do not have a protective ground. The control pressure must be at least as high as the working pressure. |
Material |
---|
Housing | Polyamide |
Seals | Acrylonitrile butadiene rubber Polyurethane |